Power Switching Requirements
Power for the individual instruments will be supp;ied via magnetically
latching relays.
-
Intruments requiring less than 0.75 Amperes @ +28 Vdc nominal will be inplemented
with Teledyne 122c Relays.
-
122c Relay are rated at switching 1 Amp loads @ +28 Vdc
-
122c Relay switching time: 4.0 milliseconds
-
122c Relay contact bounce time: 1.5 milliseconds
-
122c Relay release time: 7.5 milliseconds
-
122c Relays have the following environmental Specifications
-
Vibration: 30 g's, 10 to
3000 Hz
-
Shock:
100g's for 6 milliseconds half-sine pulse
-
Acceleration: 75 g's
-
Temperature: -65°C to +125°
Power for the individual instruments or devices requiring more than 0.75
A @ +28Vdc and less than 1.75 A @ +28Vdc will be implemented with direct
drive relays.
-
Instruments requiring more than 0.75 amperes @ +28 Vdc nominal will be
implemented with Teledyne CD1CF Solid State Relays with output status feedback.
-
CD01CF Solid State Relays are rated at switching 2 Amp loads @ +28 Vdc
-
CD01CF Solid State Relay switched voltage drop: 0.75 Vdc
-
CD01CF Solid State Relay On Resistance: 0.22 Ohms Max
-
CD01CF Solid State Relay On Time: 1.5 milliseconds
-
CD01CF Solid State Relay Off Time: 0.25 milliseconds
-
Relays have the following Environmental Specifications:
-
Vibration: 100 g's, 10 to 3000 Hz
-
Shock: 1500 g's for 0.5 msec half-sine pulse
-
Constant Acceleration: 5000 g's
-
Temperature: -55°C to +105°C
Power for the individual instruments or devices requiring more than 1.75
A @ +28Vdc and less than 4.75 A @ +28Vdc will be implemented with direct
drive relays.
-
Instruments requiring more than 1.75 Amperes @ +28 Vdc nominal will be
implemented with Teledyne KD02CK Solid State Relays with output status
feedback
-
KD02CK Solid State Relays are rated at switching 5 Amp loads @ +28 Vdc
-
KD02CK Solid State Relay switched voltage drop: 0.70 Vdc
-
KD02CK Solid State Relay On Resistance: 0.075 Ohms Max.
-
KD02CK Solid State Relay On time: 5 milliseconds
-
KD02CK Solid State Relay Off time: 2 milliseconds
-
Relays have the following Environmental Specifications:
-
Vibration: 100 g's, 10 to 3000 Hz
-
Shock: 1500 g's for 0.5 msec half-sine pulse
-
Constant Acceleration: 5000 g's
-
Temperature: -55°C to +105°C